Cisco Cisco Nexus 7000 Series Network Analysis Module (NAM-NX1) Guia Da Instalação

Página de 5
 
FPGA/EPLD Upgrade Note for Cisco Prime NAM-NX1 6.0 
 
 
 
Page  4  
 
During the upgrade, the user is prompted twice with the question: Do you want to continue (y/n). Please enter y to 
continue.
 
The NAM-NX1 will be held in down state for about 1 hour 30 minutes. After upgrade, the NAM-NX1 
will reboot online with the new FPGA image. 
your-nam # install all epld bootflash:n7000-s1-epld.6.2.5.FH.0.66.img parallel module 5 
 
WARNING: Executing the "install all epld" command may result in multiple modules going offline 
and affect redundant links. 
 
It is strongly recommended to use one of the following when an FPGA image upgrade is attempted on 
a system carrying production traffic. 
 
1) "install module <mod#> epld" 
2) "install all epld <uri> parallel module <mod#>" 
   where <mod#> is on a single module 
 
For FPGA/EPLD upgrade best practices, see 
http://www.cisco.com/en/US/docs/switches/datacenter/sw/best_practices/cli_mgmt_guide/epld_upgrade
.html
 
Do you want to continue (y/n) ?  [y
 
Compatibility check: 
Module  Type  Upgradable        Impact   Reason 
------  ----  ----------    ----------   ------ 
     5    LC         Yes    disruptive   Module Upgradable 
 
Retrieving EPLD versions... Please wait. 
 
Images will be upgraded according to following table: 
Module  Type           EPLD      Running-Version   New-Version  Upg-Required 
------  ----  -------------      ---------------   -----------  ------------ 
     5    LC  Power Manager              2.008       2.008           No 
     5    LC  IO                         2.003       2.003           No 
     5    LC  DPFPGA-0                   0.005       0.062          Yes 
     5    LC  DPFPGA-1                   0.005       0.062          Yes 
     5    LC  IO-2                       3.001       3.001           No 
The above modules require upgrade. 
This upgrade will take up to 1 hour 30 minutes if LC DPFPGA-0/1 listed above requires upgrade. 
Do you want to continue (y/n) ?  [y
Starting Module 5 EPLD Upgrade 
Module 5 : DPFPGA-0 [Upgrade Started  ] 
Module 5 : DPFPGA-0 [Erasing          ] : 100.00%  
Module 5 : DPFPGA-0 [Programming      ] : 100.00% (68091048 of 68091048 total bytes) 
Module 5 : DPFPGA-1 [Upgrade Started  ] 
Module 5 : DPFPGA-1 [Erasing          ] : 100.00%  
Module 5 : DPFPGA-1 [Programming      ] : 100.00% (68091048 of 68091048 total bytes) 
 
 Module 5 Upgrade Done. 
 
 
Waiting for Module 5 to come online. 
Module 5 EPLD upgrade is successful.