Cisco Cisco UCS B260 M4 Blade Server Ficha De Dados

Página de 74
Cisco UCS B200 M4 Blade Server
16
CONFIGURING the SERVER
Select the memory mirroring option (N01-MMIRROR) as shown in 
.
Caveats
System speed is dependent on how many DIMMs are populated per channel and the CPU 
DIMM speed support. See 
 for details.
Notes...
1. Not recommended (for performance reasons)
NOTE:  System performance is optimized when the DIMM type and quantity are equal 
for both CPUs, and when each populated channel is filled completely equally across 
the CPUs in the server.
Table 5   2133-MHz DIMM Memory Speeds with Different v3 CPUs
DIMM Speed DPC
1600-MHz Capable CPU 1866-MHz Capable CPU 2133-MHz Capable CPU
LRDIMM 
(QR)
RDIMM 
 
(8R, DR, SR)
LRDIMM 
(QR)
RDIMM 
 
(8R, DR, SR)
LRDIMM 
(QR)
RDIMM (8R, DR, SR)
2133 DIMM
1DPC
1600
1600
1866
1866
2133
2133
2DPC
1600
1600
1866
1866
2133
2133
3DPC
1600
1600
1600
1600
1866
1866 
 
(32 GB RDIMMs and 
16 GB DIMMs)
1600 
 
(64 GB TSV RDIMMs, 
8 GB RDIMMs)