Cisco Cisco Email Security Appliance C170 Guia Do Utilizador

Página de 400
 
B-5
Cisco IronPort AsyncOS 7.6 for Email Advanced Configuration Guide
OL-25137-01
Appendix B      Accessing the Appliance
Accessing via a Serial Connection
If you are connecting to the appliance via a serial connection (see “Connecting to the Appliance” in the 
Cisco IronPort AsyncOS for Email Configuration Guide), 
 illustrates the pin numbers for the 
serial port connector, and 
 defines the pin assignments and interface signals for the serial port 
connector. 
Figure B-2
Pin Numbers for the Serial Port
Table B-2
Serial Port Pin Assignments
Pin
Signal 
I/O
Definition
1
DCD
I
Data carrier detect
2
SIN
I
Serial input
3
SOUT
O
Serial output
4
DTR
O
Data terminal ready
5
GND
n/a
Signal ground
6
DSR
I
Data set ready
7
RTS
I
Request to send
8
CTS
O
Clear to send
9
RI
I
Ring indicator
Shell
n/a
n/a
Chassis ground