Samsung AR12FSFKBWTX Manual Do Utilizador

Página de 53
27
ENGLISH
Maintaining the air conditioner
If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition.
1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours 
and cut-off the power supply. There may be internal damage if moisture is left 
in components.
2. Before using the air conditioner again, dry the inner components of the air 
conditioner again by running in Fan mode for 3 to 4 hours. This helps remove 
odors which may have generated from dampness.
Periodical checks
Refer to the following chart to maintain the air conditioner properly.
Type
Description
Every 2 
weeks
Every 3 
months
Every 4 
months
Once a year
Indoor 
unit
Clean the Full HD filter (1)
Clean the condensate drain pan (2)
Thoroughly clean the heat exchanger (2)
Clean the condensate drain pipe (2)
Replace the remote controller batteries (1)
 
Outdoor 
unit
Clean the heat exchanger on the outside of the unit (2)
Clean the heat exchanger on the inside of the unit (2)
Clean the electric components with jets of air (2)
Verify that all the electric components are firmly 
tightened (2)
Clean the fan (2)
Verify that all the fan assembly is firmly tightened (2)
Clean the condensate drain pan (2)
CAUTION
Periodical checks marked with a square should be performed more 
frequently if the area of installation is very dusty.
Periodical checks marked with a circle should be performed in line 
with guidance.
Periodical checks marked with a spot should be performed by 
qualified personnel.
In accordance with local guidelines, for the products listed within 
this manual, spare parts will be made available for 10 years after the 
official manufacturers End of Life (EOL) date.
Junfrau EE_AR09FSFK@_IB&IM_DB68-06190A-00_EN.indd   27
2016/5/5   13:34:23