Generic Information
 
LTPH-UM-1234-01
10
April 30, 2003
 HDU-409 Lists 1, 2, and 3
3
This rule minimizes power consumption and dissipation from the HLU 
providing doubler power. It requires the spans closer to the HLU to be as 
short as possible and the spans farther from the HLU to be as long as 
possible. This choice minimizes the I
2
R loss in the cable pairs and 
reduces the thermal stress on the HLU.
The HDU-409 can be housed in a variety of outdoor enclosures manufactured 
by ADC and a variety of other vendors. The number of doublers used in any 
of the enclosures depends on the maximum outside ambient temperature. The 
doubler capacities for several of these standard enclosures are listed in 
, and 
 starting on 
. The capacities listed in 
 are based on a maximum outside temperature of +115°F
(+46.1°C). Consult ADC for the latest deployment rules when using the 
enclosures at ambient temperatures above 115 °F or when using enclosures 
not listed. 
The capacities listed for the indoor enclosures in 
 assume 
no solar load. The capacities listed for the outdoor enclosures in 
 and 
 assume a full solar load as described above. The 
“Recommended Slot Assignment for Maximum Capacity” column assigns 
slots according to the following thermal stress reduction rules:
Only those HRUs that have a local powering option can be 
used in local HRU-powered applications.
These requirements comply with Bellcore standards, which 
require HDSL equipment placed in outdoor cabinets to 
operate in an outside ambient temperature of -40°F (-40°C) 
with no solar load and +115°F (+46.1°C) with a maximum solar 
load and maximum power dissipation. 
Full solar load is equal to maximum sunlight exposure as 
defined in Bellcore’s Technical Advisory TR-TSY-000057.