kymco mo zx50 Manual Do Serviço

Página de 9
16
. INSTRUMENT/SWITCHES/LIGHTS
16-3
ZX / SCOUT 50
INSTALLATION
The installation sequence is the reverse of
removal.
OIL METER
INSPECTION
Remove the met-in box. (12-4)
Remove the frame body cover. (12-4)
Disconnect the oil meter wire connectors
and remove the oil meter.  Keep the oil
meter float at the lower position.
Measure the resistances between the wire
terminals as  and  shown in the left
figure.
Wire Terminals
Resistance
Green/Red(+)_
Black(-)
5_
16Ω
Green(-)_
Black(+)
Oil Meter Operation Inspection
Connect the oil meter wire connectors and
turn the ignition switch ON.
Measure the resistance between the wire
terminals with the float at upper position.
Green/Red(+)_
Black(-) About 340Ω
Light OFF
Light ON
Retainer
G
G
Float
G/R
B
B
Oil Meter
4.5± 1.0m
m