Electrical Requirements
70304601
40
Electrical Requirements for Gas and 
Steam Models
NOTE: Minimum wire sizes are obtained from 
Canadian Electrical Code for 75°C Conductors and 
are intended for use as a guideline only. Electrical 
connections should be made only by a qualified 
electrical contractor in accordance with all 
applicable local and national requirements.
For T30 Gas and Steam Models 
(For Total Machine):
NOTE: Electrical specifications below are subject 
to change without notice. Always refer to product 
serial plate for most current specifications of 
product being installed.
NOTE: Use copper conductors only.
NOTE: 3 Phase Only – Each tumbler must be 
connected to its own individual branch circuit 
breaker, not fuses, to avoid the possibility of “single 
phasing” and causing premature failure of the 
motor(s).
Table 10 
Serial Plate 
Voltage
Terminal Block
Connections 
Required
Current 
(Amps)
Recommended 
Fuse or 
Breaker Rating 
(Amps)
Breaker 
Poles
Recommended 
Minimum
Conductor Size
[AWG (mm
2
)]
120V/60 Hz/1ph
L1, Neutral, 
and ground
16.0
20
1
12 (3.31)
208-240V/60Hz/
1ph
L1, L2, Neutral, 
and ground
8.0
10
2
14 (2.08)
100V/60Hz/1ph
L1, Neutral, 
and ground
22.0
30
1
10 (5.26)
200-220V/60Hz/
1ph
L1, Neutral, 
and ground
11.6
15
1
14 (2.08)
100V/50Hz/1ph
L1, Neutral, 
and ground
24.2
35
1
8 (8.37)
200V/50Hz/1ph
L1, Neutral, 
and ground
15.0
20
1
12 (3.31)
230-240V/50Hz/
1ph
L1, Neutral, 
and ground
15.0
20
1
12 (3.31)
200-208V/60Hz/
3ph
L1, L2, L3, 
and ground
6.4
10*
3
14 (2.08)
240V/60Hz/3ph
L1, L2, L3, 
and ground
6.4
10*
3
14 (2.08)
200V/50Hz/3ph
L1, L2, L3, 
and ground
5.8
10*
3
14 (2.08)
230-240V/50Hz/
3ph
L1, L2, L3, 
and ground
7.0
10*
3
14 (2.08)
380V/50 or 60Hz/
3ph
L1, L2, L3, 
and ground
3.0
10*
3
14 (2.08)
400-415V/50Hz/
3ph
L1, L2, L3, 
and ground
3.2
10*
3
14 (2.08)
460-480V/60Hz/
3ph
L1, L2, L3,
and ground
3.3
10*
3
14 (2.08)
*
3 Phase machines should not have fuses, breakers only.