EnGenius Technologies durafon 1x Manual Do Utilizador

Página de 54
~45~
(2) When finished; press 
SAVE
 to save change. 
 
g.  Press “7” to change the LCD backlight: 
(1) Use 
¿orÀ to scroll through options: On, Off, and 8 Seconds.  Default = 
6 seconds, meaning that the backlight will turn off the backlight after 8 
seconds of inactivity. 
(2) When finished; press 
SAVE
 to save change. 
 
h.  Press “8” to edit Call Barring 
(1)  Need to Enter Password to edit the call barring code to be executed. 
The default PW is “0000.” 
(2)  Please refer to page 37 for detail operation.  
 
i. 
Press “9” to enable Name tag 
(1) Use 
¿orÀ to switch between On and Off.  The default setting is Off.  
(2) When finished; press 
SAVE
 to save change. 
 
j. 
Press “0” to program PBX features that you use frequently 
(1)  Program and save the most frequently used PBX function into DuraFon 
system 
(2)  Please refer to page 39 for detail operation.  
 
 
 
7.  Press “6” to register or de-register handset and base:  See the detail 
instructions on page 30
.
 
 
 
8.  Press “7” to view inbox text message(s) or edit outbox text message(s). 
See the detail instructions on page 38
.
 
 
 
9.  Press “8” to enter Call Manager setting.  
 
a.  Press “1” to edit “incoming call” setting. See the detail instructions 
on page 34.
 
b.  Press “2” to edit “outgoing call” setting. 
(1)  Once activate Select BS function, you need to enter the base ID which 
you want to choose for an outgoing call.  
(2)  The default setting is OFF.  
 
 
 
10.  Press “9” following by entering a base ID to enter System setting. See 
the detail instructions on page 34
.
~46~
Technical Specifications 
Electrical Specifications
Base Station 
Portable Handset 
Frequency 
902-928 MHz 
902-928 MHz 
RF Power 
Peak: 708 mW 
Average:
ˊˉ mW 
Peak: 708 mW 
Average: 76 mW 
Channel Spacing 
200 kHz 
200 kHz 
Number of Channels 
128 
128 
Modulation MSK 
MSK 
Multiple Access 
Frequency Hopping TD
˗
Frequency Hopping TD
˗
Frequency Hopping 
Rate
100 per second 
100 per second 
TDMA Frame Length
10 ms 
10 ms 
Number of Slots/Frame
Receiver Sensitivity 
< -108 dBm (@ BER 10
-2
)
< -108 dBm (@ BER 10
-2
)
Antenna Connector 
Reverse TNC 
Non-standard 
Antenna Gain 
2 dBi 
5 dBi External (optional)
0.5 dBi (short antenna) 
2 dBi (tall antenna) 
TX Power Control 
Range
NA 100-708 
mW 
Telephone Interface 
RJ11 x 2 
NA 
Speech Coding 
8 kbps G.729A 
8 kbps G.729A 
Channel Coding 
8 kbps Convolutional + 
CRC
8 kbps Convolutional + 
CRC
Transmission Data Rate
170.678 kbps 
176.678 kbps 
User Data Rate 
128 kbps duplex 
128 kbps duplex 
Duplex 
Time Division Duplex 
(TDD) 
Time Division Duplex 
(TDD) 
Voice Quality 
TIA/EIA-470B 
TIA/EIA-470B 
No. of System ID 
65,536 
65,536 
Ring Signal 
20-50 Hz, 12-90 Vrms 
NA 
Flash Time 
100-900 ms 
programmable 
NA
Power Source 
120V/12V AC/DC Adapter
3.6 V, 1700 mAh Li-ion 
Battery 
Charger Current 
NA 
ˉ00 mA 
Charge Time 
NA 
4 hours (from empty) 
Regulation Compliance
FCC Part 15, Part 68 
CAN/DOC RSS210, CS03
FCC Part 15, Part 68 
CAN/DOC RSS210, CS03 
Hearing Aid Compatible 
Operating Temperature
-10 – 60 
qC 
-10 – 60 
qC
Storage Temperature
-10 – 70 
qC 
-10 – 70 
qC
Humidity 
20 – 75 % 
20 – 75 % 
Dimension with antenna
188*161*42mm 
161*58*31mm 
Weight 424g 
175g 
Notes:
1. 
NA = Not Applicable. 
2. 
The manufacturer reserves the right to change designs and specifications without notice.