Alliance Laundry Systems 1305 Manual Do Utilizador

Página de 111
Allen-Bradley 1336-Series AC Drives
F232120
86
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Terminal Block Access
The following information illustrates the terminal 
block designations for each of the drive models.
To access the power and control terminal blocks, 
perform the following procedure:
1. Remove power from machine at main 
disconnect. Verify power light is off.
2. Loosen the front cover fastener located at the 
base of the front cover. Refer to Figure 48.
3. Lift off cover.
NOTE: HIM unit extension unit cable inserts into 
separate port for 1305 and 1336 A-B drives.
Figure 48 
WARNING
To reduce risk of electric shock, severe 
injury or death, allow machine power to 
remain off for three minutes minimum prior 
to working in and around AC drive. Proceed 
with caution.
W662
Front Cover
TB3
TB2 TB1
TB3 TB2 TB1
ES
C
SE
L
Stopped
+0.00 Hz
ES
C
SE
L
Stopped
+0.00 Hz
U077ME3B
A-B 1336
A-B 1336