504524
11
STEP 3: (Gas Dryer ONLY)
Connect Gas Supply Pipe
For further assistance, refer to Section on Gas 
Requirements
.
1. Make certain dryer is equipped for use with the type 
of gas in laundry room. Dryer is equipped at the 
factory for Natural Gas with a 3/8" NPT gas 
connection.
2. Remove the shipping cap from the gas connection at 
the rear of the dryer. Make sure you do not damage 
the pipe threads when removing the cap.
3. Connect to gas supply pipe. 
4. Tighten all connections securely. Turn on gas and 
check all pipe connections (internal & external) for 
gas leaks with a non-corrosive leak detection fluid. 
5. For L.P. (propane) gas connection, refer to Section on 
Gas Requirements.
3/8" NPT
GAS CONNECTION
1/8" NPT
PIPE PLUG
(For checking
inlet gas pressure)
NEW 
STAINLESS STEEL
FLEXIBLE
CONNECTOR
 USE ONLY 
IF ALLOWED 
BY LOCAL
CODES 
(Use
Design A.G.A.
Certified
Connector)
EQUIPMENT
SHUT-OFF
VALVE
Install within 
6' (1.8 m) of dryer
D233IE3D
                 BLACK IRON PIPE
Shorter than 20' (6.1 m) - use 3/8" pipe
Longer than 20' (6.1 m) - use 1/2" pipe