Alliance Laundry Systems d355ie1b Manual Do Utilizador

Página de 88
12
504524
STEP 4: (ELECTRIC DRYER ONLY)
Connect Electrical Plug
For further assistance, refer to Section on Electrical 
Requirements
.
IMPORTANT:  Use only a new U.L. listed No. 10 
(copper wire only) three conductor power supply cord 
kit rated 240 Volts (minimum) 30 Amperes and 
labeled as suitable for use in a clothes dryer.
NOTE: For more detailed information on connecting 
three-wire or four-wire plugs, refer to Section on 
Electrical Plug Connection
.
NOTE: Four-wire cord is required for mobile homes 
or where codes do not permit grounding through 
neutral.
STRAIN 
RELIEF
NUT
TYPICAL
THREE-WIRE
RECEPTACLE
POWER CORD
(Three-Wire)
STRAIN
RELIEF
D275IE0D
Three Wire
Three Wire
NUT
TYPICAL
FOUR-WIRE
RECEPTACLE
POWER CORD
(Four-Wire)
STRAIN
RELIEF
D006IE0A
STRAIN 
RELIEF
Four Wire
D276IE1A
CENTER
WIRE
(NEUTRAL)
STRAIN
RELIEF
(NOT SUPPLIED 
WITH DRYER)
NEUTRAL
TERMINAL
GROUND
WIRE
"L2"
TERMINAL
"L1"
TERMINAL
GROUND 
SCREW
GROUND
TO NEUTRAL
WIRE
Three-Wire Connection
D171IE1A
WHITE
WIRE
(NEUTRAL)
GROUND 
SCREW
NEUTRAL
TERMINAL
"L1"
TERMINAL
BLACK
WIRE
GROUND
WIRE
STRAIN
RELIEF
(NOT SUPPLIED
WITH DRYER)
GROUND
WIRE
"L2"
TERMINAL
RED
WIRE
Four-Wire Connection
NOTE: Dryer is shown with access cover removed for illustration purposes only. NEVER operate dryer with 