504524
Heat Source Check . . .
(Electric Dryers)
Metered Models
Set the proper FABRIC SELECTOR switch at 
NORMAL. Place coins in the slide and carefully push 
slide in as far as possible. IN USE light will come on 
indicating the dryer is ready to operate. Close the loading 
door and press the PUSH-TO-START button firmly to 
start the dryer. After either dryer has operated for three 
minutes, the exhaust air or exhaust pipe should be warm.
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and turn 
timer knob to 50. Close the loading door and press the 
PUSH-TO-START button. IN USE light will come on 
indicating start of cycle. After either dryer has operated 
for three minutes, the exhaust air or exhaust pipe should 
be warm.
(Gas Dryers)
During the gas heat check, observe the burner flame. The 
flame can be viewed by removing the lower front panel of 
the dryer.
Metered Models
Set FABRIC SELECTOR switch at NORMAL. Place 
coins in the slide and carefully push slide in as far as 
possible. IN USE light will come on indicating the dryer 
is ready to operate. Close the loading door and press the 
PUSH-TO-START button firmly. The dryer will start, the 
igniter will glow red and the main burner will ignite. 
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and turn 
timer knob to 50. Close the loading door and press the 
PUSH-TO-START button. IN USE light will come on 
indicating start of cycle, igniter will glow red and main 
burner will ignite.
IMPORTANT: If all air is not purged out of the gas 
line, the gas igniter may go off before the gas is 
ignited. If this happens, after approximately two 
minutes the igniter will again attempt gas ignition.
All Models
After either dryer has operated for approximately five 
minutes, observe burner flame. Adjust the air shutter to 
obtain a soft, uniform blue flame. (A lazy, yellow tipped 
flame indicates lack of air. A harsh, roaring, very blue 
flame indicates too much air.) Adjust the air shutter as 
follows:
1. Loosen the air shutter lockscrew.
2. Turn the air shutter to the left to get a luminous 
yellow tipped flame, then turn it back slowly to the 
right to obtain a steady soft blue flame.
3. After the air shutter is adjusted for proper flame, 
tighten the air shutter lockscrew securely.
4. Reinstall the lower front panel.
After either dryer has operated for approximately three 
minutes, the exhaust air or exhaust pipe should be warm.
For personal safety, lower front panel must be 
in place during normal operation.
W046
WARNING
D157IE3C
AIR
SHUTTER
1/8" (3.1 mm)
PIPE PLUG 
(For checking
manifold pressure)
OPEN
POSITION
CLOSED 
POSITION
SHUT-OFF
VALVE 
HANDLE
AIR SHUTTER