Location Requirements . . .
Select a location with a solid floor.
No other fuel burning appliance should be installed in the 
same closet with the dryer unit.
The dryer unit must not be installed or stored in an area 
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer unit 
with a 1/4" driver. All four legs must rest firmly on the 
floor so the weight of the dryer is evenly distributed. The 
dryer unit must not rock.
IMPORTANT: Unless completely assembled, DO 
NOT slide the dryer unit across the floor. DO NOT 
slide the unit once the leveling legs have been 
extended, as the legs and the base could become 
damaged.
The dryer unit needs sufficient clearance and an adequate 
air supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown below.)
NOTE: Shaded areas
indicate adjacent structure.
A
A
D358IE2A
B
C
E
E
D
Dryer And Exhaust Duct Clearances
Area
Description
Minimum 
Clearance
A
Dryer Sides
0" (0 cm)
B
Dryer Top (Rear 24")
2" (5.1 cm)
C
Dryer Rear
4" (10.2 cm)
D
Dryer Top (Front 4")
0" (0 cm)
E
Exhaust Duct from Combustible Construction
2" (5.1 cm)