Exhaust System
IMPORTANT:  Keep exhaust duct as short as 
possible.
NOTE:  Be certain old ducts are cleaned before 
installing your new dryer unit.
For best drying results, recommended maximum length 
of exhaust system is shown below.
To prevent backdraft when dryer unit is not in operation, 
outer end of exhaust pipe must have a weather hood with 
hinged dampers (obtain locally).
NOTE:  Weather hood should be installed at least 12 
inches (30.5 cm) above the ground. Larger clearances 
may be necessary in areas where heavy snowfall can 
occur.
Exhaust Direction
The dryer unit can be exhausted to the outdoors through 
the back, left, right or bottom of the dryer unit. 
EXCEPTION: Gas dryers cannot be vented out the 
left side because of the burner housing.
Dryer unit is shipped from factory ready for rear exhaust; 
no kits required
.
Exhausting the dryer through sides or bottom (lower 
dryer only) can be accomplished by installing a 
Directional Exhaust Kit 528P3 available as optional 
equipment at extra cost.
WEATHER 
HOOD
WITH 
HINGED
DAMPERS
RIGID OR
FLEXIBLE
METAL
DUCT
D186IE0A
528P3 Directional Exhaust Kit
Number of 
90° Elbows
Weather Hood Type
Recommended
Use only for short run installations
Maximum length of 4" (10.2 cm) diameter rigid metal duct.
0
44 feet (13.4 m)
34 feet (10.4 m)
1
34 feet (10.4 m)
26 feet (7.9 m)
2
26 feet (7.9 m)
20 feet (6.1 m)
3
20 feet (6.1 m)
14 feet (4.3 m)
Maximum length of 4" (10.2 cm) diameter flexible metal duct.
0
24 feet (7.3 m)
20 feet (6.1 m)
1
20 feet (6.1 m)
16 feet (4.9 m)
2
16 feet (4.9 m)
12 feet (3.7 m)
3
12 feet (3.7 m)
8 feet (2.4 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.
D011IE2D
4"
(10.16 cm)
4"
(10.16 cm)
D011IE2E
2-1/2"
(6.35 cm)