Ariens 991040 - Zoom 2660 HD Manual Do Utilizador

Página de 34
GB - 18
HYDRAULIC FLUID
Check Hydraulic Fluid Level
Check the system with the unit cold and 
parked on a flat, level surface. 
Then run the unit for about one minute and 
recheck the levels.
To Add Hydraulic Fluid:
1. Remove the cap from the expansion 
tank.
2. Fill the expansion tank with Mobil 1 
Extended Performance 15W50 or 
equivalent (Ariens p/n 00057100) until 
oil level reaches the cold fill line on the 
tank.
3. Install the expansion tank cap and then 
Change Hydraulic Fluid and Filter
NOTE: Change hydraulic fluid and filter after 
first 75 hours of operation. Change the 
hydraulic oil filter and hydraulic oil every 400 
hours. Use Mobil 1 Extended Performance 
15W50 Synthetic Oil or equivalent for best 
component life (Ariens p/n 00057100).
1. Place container under oil filter to catch 
oil.
2. Remove the filter guard and oil filter from 
the transaxle. 
3. Remove the oil drain plug or fitting from 
the inlet port and allow the transaxle to 
drain completely. 
4. Clean the filter mounting surface and 
then lubricate rubber gasket on new oil 
filter with clean hydraulic oil.
WARNING: HYDRAULIC FLUID 
can result in severe burnsFluid 
in hydraulic system can penetrate 
skin and result in serious injury or 
death.
Be sure to stop the engine before 
doing any work on hydraulic 
parts.
Keep body and hands away from 
pin holes or nozzles which expel 
hydraulic fluid when under 
pressure. Use paper or 
cardboard, not hands, to search 
for leaks.
Ensure all hydraulic fluid 
connections are tight and all 
hydraulic hoses and lines are in 
good condition before applying 
pressure to system.
FOREIGN FLUID INJECTED 
INTO BODY can result in 
gangrene. Fluid must be 
surgically removed within a few 
hours by a doctor familiar with 
this form of injury.
1. Service 
Position
2. Steering 
Levers
3. Parking Brake
4. Battery
Figure 6
OM4110
Figure 7
The hydraulic fluid should be at the cold 
fill line of the expansion tank.