To Program a Short Test Cycle:
1. Unplug machine power cord.
2. Write down machine control dip switch settings, 
then set them all to the off position. Refer to 
Figure 4.
3. Plug machine in and start a cycle. 
NOTE: With all control dip switches off, the total 
cycle time will be 1 minute long.
4. Once all testing is complete, unplug machine and 
re-set dip switches to their original settings.
5. Plug machine in.
Figure 4 
Error Codes
TMB2216N
1 2 3 4 5 6 7 8
O
N
1
2345
6
78
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Display
Definition
Corrective Action
OP
Open thermistor error
Check thermistor. Replace if inoperative.
Check wiring diagram between control and 
thermistor. Refer to wiring diagram for proper 
wiring.
Check control. Replace if inoperative.
SH
Shorted thermistor error
Check thermistor. Replace if inoperative.
Check wiring between control and thermistor. 
Refer to wiring diagram for proper wiring.
Check control. Replace if inoperative.
AF - 1
Airflow switch closed when cycle 
started
Check airflow switch. Replace if inoperative.
AF - 2
Airflow switch failed to close after 
cycle started
Check airflow switch. Replace if inoperative.