Alliance Laundry Systems 25 pound capacity Manual Do Utilizador

Página de 29
Operating Instructions
17
70400001
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
DMP OPL Features
DIP Switch Settings
The DMP has an 8 position DIP switch bank that is 
accessible from the back of the control board. By 
switching these DIP switches, it is possible for the 
operator to customize the display and some of the 
operating features of the tumbler. 
DIP Switch Functions Explained
1. Tumbler Type: This DIP switch selects the type 
of tumbler, i.e., OPL or Coin.
2. Temperature Units: Selects ºF or ºC for the 
temperature display. Factory setting is for ºF.
3. Local/Remote Reversing: Preset at the factory; 
usually for local reversing. Remote reversing for 
use with Reversing Timer Board only. 
4. Empty: Preset at the factory; always ON.
5. Empty: Preset at the factory; always ON.
6. Buzzer Timer: This DIP switch determines the 
length of time that the end of cycle buzzer will 
remain on. “OFF” indicates that the buzzer will 
sound for 5 seconds when the drying cycle is 
completed. “ON” indicates that the buzzer will 
sound continuously until the STOP button is 
pressed or the loading door is opened. 
7. Safety Tumble (OPL) or Coin count/Pay (Coin): 
If DIP switch #1 is set for OPL, then DIP switch 
#7 in the ON position enables the safety tumble. 
If DIP switch #1 is set for Coin, then DIP switch 
#7 in the ON position enables the display of the 
coin count. DIP switch #7 in the OFF position 
enables the display of “PAy,” to indicate that 
coins are needed to run the tumbler. 
8. Programming: This switch enables or disables 
the programming feature and should normally be 
in the OFF position.
Dip Switch
Funtion
1
Tumbler Type
ON   - Coin
OFF - OPL
2
Temperature Units
ON    -  C
OFF* -  F
3
Local or Remote Reversing
ON*   - Local Reversing
OFF   - Remote Reversing
4
Empty
ON*
5
Empty
ON*
6
Buzzer Timer
ON   - Continuous
OFF - 5 Sec
7
OPL Models - Safety Tumble
Dip Switch
#1
#7
OFF
ON
Safety Tumble
OFF
OFF
No Safety Tumble
Coin Models - Coin Count/Pay
Dip Switch
#1
#7
ON
ON
Coin Count
ON
OFF
Pay
8
Programming
ON    - Enable
OFF* - Disable
* Factory default setting
Table 2