Shutdown diagnostics
To perform shutdown diagnostics:
With the ignition OFF, press and hold the Program switch.
1. 
Turn the ignition ON and then back OFF while holding the Program 
2. 
switch.
Release the Program switch.
3. 
Press and release the Program switch. The LED reports  the last shutdown 
4. 
for one minute or until the ignition is turned on, as shown in the following 
table:
LED Flashes 
Shutdown Mode
 
Timed out 
 
Over-rev shutdown     
 
Low or no RPM
 
Transmitter shutdown (or optional push button)
 
(-)  Shutdown (H3/4 GRAY) or (+) Shutdown (H3/3    
 
 
BROWN)
 
(+) Brake shutdown 
 
(-) Neutral safety shutdown (H3/1 BLACK/WHITE)