Metrologic Instruments stratoss ms2220 Manual Do Utilizador

Página de 88
 
 
59
T
ROUBLESHOOTING 
 
 
Symptom 
Possible Cause(s) 
Solution 
All Interfaces 
The unit scans a bar code, 
but locks up after the first 
scan (the white LED stays 
on
). 
The scanner is configured to 
support some form of host 
handshaking but is not 
receiving the signal. 
If the scanner is setup to support ACK/NAK, RTS/CTS, 
XON/XOFF or D/E, verify that the host cable and host are 
supporting the handshaking properly. 
The unit scans but the 
data transmitted to the 
host is incorrect. 
The scanner’s data format 
does not match the host 
system requirements. 
Verify that the scanner’s data format matches that required 
by the host.  Make sure that the scanner is connected to the 
proper host port. 
The print quality of the bar 
code is suspect. 
Check the character length 
lock. 
Scanner beeps at some 
bar codes and NOT from 
others of the same bar 
code symbology. 
The aspect ratio of the bar 
code is out of tolerance. 
The type of printer and/or the printer settings could be the 
problem. 
 
Check the print mode or change the printer settings.  For 
example change to econo mode or high speed. 
The unit is trying to scan a 
particular symbology that is 
not enabled. 
UPC/EAN and Code 128 are enabled by default.  Verify that 
the type of bar code being read has been selected. 
The unit powers up but 
does not scan and/or 
beep. 
The unit has been configured 
for a character length lock or 
a minimum length and the bar 
code being scanned does not 
satisfy the configured criteria. 
Verify that the bar code that is being scanned falls into the 
criteria. 
 
Typical of Non-UPC/EAN codes.  The scanner defaults to a 
minimum of 4 character bar code. 
The bar code may have been 
printed incorrectly. 
Check if it is a check digit, character or border problem. 
The scanner is not configured 
correctly for this type of bar 
code. 
Check if check digits are set properly. 
The unit beeps at some 
bar codes but NOT for 
others of the same bar 
code symbology. 
The minimum symbol length 
setting does not work with the 
bar code. 
Check if the correct minimum symbol length is set.