Metrologic Instruments stratoss ms2220 Manual Do Utilizador

Página de 88
 
 
61
T
ROUBLESHOOTING 
 
 
RS232
 
D
EMONSTRATION 
P
ROGRAM 
 
 
 
If an RS232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that 
the communication port and scanner are working.  This program is for demonstration purposes only.  It is only intended to 
prove that cabling is correct, the com port is working, and the scanner is working.  If the bar code data displays on the 
screen while using this program, it only demonstrates that the hardware interface and scanner are working.  At this point, 
investigate whether the application software and the scanner configuration match.  If the application does not support 
RS232 scanners, a software wedge program that will take RS232 data and place it into a keyboard buffer may be needed.  
This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect (DCD) signals.  If the 
demonstration program works and yours still does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and 
DSR on the back of your PC. 
 
 
10 CLS 
20 
ON ERROR GOTO 100 
30 OPEN 
“COM1:9600,S,7,1,CS0,DS0,CD0,LF” AS #1 
35 
PRINT “SCAN A FEW BAR CODES” 
40 
LINE INPUT #1, BARCODE$ 
50 PRINT 
BARCODE$ 
60 
K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766 
70 GOTO 
40 
100 
PRINT “ERROR NO.”; ERR; “ PRESS ANY KEY TO TERMINATE.” 
110 
K$ = INKEY$: IF K$ = “” THEN GOTO 110 
32766 CLOSE: SYSTEM 