Interphase Tech ispan 5535 pri Manual Do Utilizador

Página de 168
3
iSPAN PRI PCI ISDN Users Guide
17
3
Connecting to the Line
Overview
The type of line your carrier provides depends on whether you 
are in North America or Europe. This chapter provides the 
following information required to connect your adapter to the 
line:
•  connection methods and requirements for connecting to 
a North American T1/PRI line
•  connection methods and requirements for connecting to 
a European E1/PRI line
•  summary of steps to connect the adapter to the network.
If you are in North America, continue with the next section. 
If you are in Europe, skip to European E1/PRI Line on 
page 23.
North America T1/PRI Line
When you connect the adapter to a North American T1/PRI 
line, first determine the appropriate connection method, 
cabling requirements, and link requirements.
Two T1/PR1 line configurations exist: DSX1 (short haul) and 
DS1 (long haul). When the distance to your carrier is short 
enough (less than 655 feet or 200 meters), you can generally 
connect the adapter in a DSX1 configuration directly to the 
T1/PR1 line. All iSPAN-PRI adapters support the DSX1 
configuration.