Intermatic ig1300 installation Manual Do Utilizador

Página de 8
STEP 19
Close the cover 
on the IG1300.
SPECIAL INSTRUCTIONS
Use the following steps when installation requires placing the IG1300 on the
left side of the electrical panel.
STEP A
Loosen the screw in hole C that secures the coaxial cable protection
module(s) to the wire channel cover. Remove the coaxial modules and set
them to one side for future use. Remove screw C completely.
STEP B
Invert the wire channel cover with the telephone line protection modules still
attached to it and place it into
the IG1300 cabinet as shown
in Figure 4. Install a Torx
screw through the hole in the
foot of the wire channel cover
and into hole E and tighten it
snugly to the back of the cabi-
net.
STEP C
Insert a Torx screw through
the elongated hole on the
coaxial protection module(s)
and into hole D as shown in
Figure 4. Do not tighten the
screw.
STEP D
Place the remaining Torx
screw through the opening on
the tab of the coaxial protec-
tion module(s) and into hole F.
Tighten the Torx screws firmly
to ensure a good ground
bond.
NOTE: 
If the telephone protection Modules are left in an inverted position as shown in
figure 4, be sure to observe the “IN” and “OUT” markings. 
STEP E
Return to Step 12.
Figure 4
5
Torx T-20
in Hole E
Torx T-20
in Hole D
Torx T-20
in Hole F
TROUBLESHOOTING and ASSISTANCE: 
Technical Services    815-675-7000 
http://www.intermatic.com