Condition / Problem
Things to Check
Solution 
Motor Bearings
Replace the motor. 
7.
No elevation up or 
elevation down or no 
elevation but will calibrate.
Elevation Calibration
See Calibration Procedure in the appendix 
section. Check the I/O cable connections 
at console and dual board.
Elevation Pot Values
During elevation calibration, you should 
see values from elevation pot in main 
display screen lower left. The values 
should count up or down during the 
elevation calibration procedure. If no 
value appears as elevation motor moves, 
then calibration will fail. Check wire from 
pot to lower control board (LCB) and gray 
wire connection in 8 PIN I/O cable. 
If value does not change as motor moves, 
then remove elevation pot and check 
for ohms reading changes as pot shaft 
is turned, from white to red and white to 
black. If ohms readings do not change 
then replace pot. If readings change test 
pot jumper. If jumper tests good replace 
elevation motor. 
Signal to LCB from Console
Apply safety key, then press the START 
button. When you press the INCLINE UP 
button, if the Up LED light on the Dual 
Board does not come on, check VDC 
between Green and Yellow wires in the 
8 PIN I/O cable. Assure Green wire is 
securely seated in all plugs. If voltage is 
present, replace LCB. If no voltage can 
be read replace Upper Electronics.  If LED 
lights up, then you will need to check the 
elevation pots at Elevation Common and 
the up post and you should be getting 120 
volts. If you are getting 120 volts then you 
will need to replace the Elevation Motor. If 
you do not get 120 volts then you will need 
to replace the LCB. 
Elevation Rheostat and the 
jumper to the Dual Board. 
Check the connectors, if good, replace: 
1st - The Elevation Rheostat and jumper 
to the Dual Board. Then calibrate the 
elevation. 
2nd - Replace the I/O cable.
3rd - Replace the Upper Electronics.
4th - Replace the Dual Board.