Two 
screws 
1)  Gain access to the oven burners (refer 
6.2.6). 
2)  Remove the four screws securing the pilot 
burner to the main burner aeration slide. 
1)  Gain access to the oven burners (refer 
6.2.6). 
2)  Remove the screw holding the electrode 
positioning bracket to the housing on the 
inside of the oven. 
3)  Pull the fan and motor assembly into the 
oven as pictured below, and disconnect 
the wiring.  The fan motor unit can now be  
removed from the oven. 
4)  Slacken the two socket head grub screws 
spaced at 90
o
 on the fan boss. 
Figure 6.3.14 
5)  Remove the fan from the motor shaft. 
NOTE:  Use of a fan puller is recommended 
for removal of the oven fan.   
6)  Re-assemble in the reverse order. 
NOTE:  No lubrication of either the fan or  
motor is required as they are both self  
lubricating. 
Figure 6.3.15 
6.3.12  IGNITION ELECTRODES 
3)  Remove the oven right hand side panel 
(refer 6.2.4). 
4)  Remove  the  two  screws  securing  the  
electrode mounting bracket to the right 
hand insulation panel. 
5)  Transfer the wires to the new electrode 
assembly  and  reassemble  in  reverse  
order. 
NOTE:   Ensure  to  correctly  set  electrode  
gapping when installing new electrodes 
and test before fully re-assembling oven. 
Between SPARK and EARTH (centre) 3-5mm 
Between EARTH and main burner 7-10mm 
Between SENSOR and EARTH 10-12mm 
Between SENSOR and main burner 7-10mm 
Figure 6.3.16 
Figure 6.3.17 
Screw 
6.3.13  PILOT BURNER 
Figure 6.3.18 
3)  Slide the pilot burner off the pilot injector. 
4)  Replace pilot burner and reassemble in 
reverse order.