Injection 
Nozzle 
Units Manufactured up to S/N 275353 
1) Remove  right  hand  side  panel  (refer 
6.2.4).   
2)  Disconnect the two wires leading to the 
gas solenoid. 
3)  Disconnect  main  gas  supply  pipe  from 
copper connection line to manifold.   
4)  Loosen pipe clamp at rear of oven and  
remove main supply pipe assy.   
5)  On work bench undo gas solenoid valve 
from assembly and replace.   
Figure 6.3.25 
Solenoid Valve 
1)  Ensure water supply is turned off. 
2)  Remove the water injection nozzle from 
inside the oven (refer 6.3.19). 
3)  Remove the water solenoid access panel 
at the rear of the oven (4 screws). 
6.3.20  WATER SOLENOID VALVE 
1)  Remove the fan baffle (refer 6.2.2). 
2)  Unscrew the water injection nozzle. 
3)  Clean or replace nozzle, and reassemble 
in reverse order. 
6.3.19  WATER INJECTION NOZZLE 
Figure 6.3.26 
Figure 6.3.27 
4)  Remove the wires from the solenoid, and 
disconnect the mains water connection. 
5)  Remove  the  two  screws  securing  the  
solenoid bracket to the oven rear, and  
remove the valve assembly. 
Figure 6.3.28 
Water  
solenoid  
access panel 
4)  Disconnect gas supply at rear of oven, 
remove saddle clamp holding the gas inlet 
pipe (two screws). 
5)  Remove the four screws securing valve 
bracket to oven, remove valve and inlet 
pipe from the oven. 
6)  Unscrew gas inlet pipe and elbow from 
the valve.  Remove the four screws (two 
top and bottom) securing the valve to the 
bracket, remove valve. 
7) Fit  new  valve  to  the  bracket  and  
re-assemble in reverse order. 
8)  Leak test all new connections. 
Figure 6.3.24 
Gas Inlet Pipe 
Wiring Plug 
Flex-tube 
Gas Valve 
(four screws) 
Valve Bracket 
(four screws) 
6)  Refit and reconnect solenoid wires using 
reverse procedure.   
7)  Leak test all new connections.