Installation - Models IHF100 and
IHF135
IHF135
Ground
The machine must be placed on a flat, solid surface
(metal base, concrete or solid ground). It is
recommended that the machine be anchored (M16) on
the provided places (1) in the base, especially in case
of a plinth. Refer to Figure 14.
Figure 14
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
Electrical Installation Requirements
- Models IHF100 and IHF135
- Models IHF100 and IHF135
Table 3
CHM2180N
1
Mounting Bolt Holes
1
Machine without electrical heating
220V 3AC
380V 3AC + N
20 A
20 A
Machine with electrical heating
220V 3AC
380V 3AC + N
27 kW
80 A
63 A
36 kW
N/A