PI
Module -  iConverter GX/TM2                      iConverter, Serial Agent
 Identifier -
 Chassis Number
= 1
Switch
ON Condition
OFF Condition
H/W
Actual
 Slot Number
= 7
1: Port 1 Manual
Port 1 AN
Off
Off
 Model Number
= 8939N-0
2: Port 2 Manual
Port 2 AN
Off
Off
3: Port 2 10/100
Port 2 1000
Off
Off
 Serial Number
= xxxxxxxx
4: Port 2 10
Port 2 100
Off
Off
 Manufacturing Date = xxxxxxxx
5: Port 2 HDX
Port 2 FDX
Off
Off
 Product Revision
= xx
6: Link Propagate
Link Segment
Off
Off
 Software Revision
= xx
7: Remote Fault
Normal
Off
Off
8: Symm Fault Det
Normal
Off
Off
 LED
9: BP A Enabled
BP A Disabled
On
On
 1: Power
= On
10: BP B Enabled
BP B Disabled
On
On
 2: Power Supply 1
= Off
11: Slave Only
Master/Slave
Off
Off
 3: Power Supply 2
= On
12: Not Available
 4: Power Supply 3
= Off
Configuration Setting
 5: Port 1 Link
= Off
13: Pause Function
Disabled
 6: BP Master
= On
14: Not Available
 7: UTP 100+10 Link = Off
15: Not Available
 8: UTP 1000+10 Link= Off
16: Not Available
 9: UTP FDX
= Off
17: IP Protocol State  Off
18: Management Mode    ah OAM
 Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
The Module configuration screen provides general information concerning the configuration and status of
the module.  The screen displays the model and serial numbers, hardware and software revisions, as well as
the condition of the LEDs and DIP-switches.  The DIP-switches can be re-configured (options 1 -11)
without removing the module from the chassis.  Select the appropriate option to change the DIP-switch
setting.  Selecting DIP-switch options 1 - 11, will cause the selection to change states under the ‘Actual’
heading.
NOTE:  The Plug-In Module configuration screen is shown.  The standalone Module configuration
screen will display LED 2, 3, 4, and 6 and DIP-switches 9, 10 and 11 as NOT AVAILABLE.
4.1.1
Pause Setting (Configuration Setting 13)
The Pause Function switch sets the flow control functionality for the module, including pause mode
advertisement, pause functionality, and half duplex jam. When set to Enable, flow control functionality is
enabled. When set to Disable, flow control functionality is disabled.
If Pause is Enabled on the module and the port is in half duplex then half duplex flow control is enabled.
When a port is in half duplex flow control it generates a “jam” signal when a collision is detected.
If Pause is Enabled on the module and the port is in full duplex then full duplex flow control is enabled.
When a port is in full duplex flow control and internal buffering resources are low a pause frame is generated
to slow down the traffic flow to the port.