omnitron-systems-technolo gx-tm2 Manual Do Utilizador

Página de 48
4.1.2
Module Management Mode (Configuration Setting 17 and 18)
From the Module configuration screen, the management mode can be changed.  Select option 18 to change
the mode.  The management mode options will be displayed.
PI
Module -  iConverter GX/TM2                      iConverter, Serial Agent
 Identifier -
 Chassis Number
= 1
Switch
ON Condition
OFF Condition
H/W
Actual
 Slot Number
= 7
1: Port 1 Manual
Port 1 AN
Off
Off
 Model Number
= 8939N-0
2: Port 2 Manual
Port 2 AN
Off
Off
3: Port 2 10/100
Port 2 1000
Off
Off
 Serial Number
= xxxxxxxx
4: Port 2 10
Port 2 100
Off
Off
 Manufacturing Date = xxxxxxxx
5: Port 2 HDX
Port 2 FDX
Off
Off
 Product Revision
= xx
6: Link Propagate
Link Segment
Off
Off
 Software Revision
= xx
7: Remote Fault
Normal
Off
Off
8: Symm Fault Det
Normal
Off
Off
 LED
9: BP A Enabled
BP A Disabled
On
On
 1: Power
= On
10: BP B Enabled
BP B Disabled
On
On
 2: Power Supply 1
= Off
11: Slave Only
Master/Slave
Off
Off
 3: Power Supply 2
= On
12: Not Available
 4: Power Supply 3
= Off
Configuration Setting
 5: Port 1 Link
= Off
13: Pause Function
Disabled
 6: BP Master
= On
14: Not Available
 7: UTP 100+10 Link = Off
15: Not Available
 8: UTP 1000+10 Link= Off
16: Not Available
 9: UTP FDX
= Off
17: IP Protocol State  Off
18: Management Mode    ah OAM
 Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3
The GX/TM2 module supports several management options.  Option 18 configures how the module will
communicate to its remote partner.  ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses
Omnitron’s proprietary secure encrypted management channel.  ‘Auto Secure OAM’ will force the remote
partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to
communicate with the remote partner over the secure protocol.  The management channel can support IP or
IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17.  ‘Auto ah OAM’
(option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification.  ‘Auto ah OAM’ will
force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to
communicate with the remote partner over the ah protocol.  This option provides an industry standard
method of fault detection and monitoring.  The management channel supports both IP and IP-less connectivity
based on the configuration, option 17 and 18.
NOTE:  See the NetOutlook user manual for complete information on the management modes.
Page 27