Lennox merit lmbv-36rmp Manual Do Utilizador

Página de 16
2
LENNOX MERIT
®
 SERIES B-VENT GAS FIREPLACES   •   36" LMBV MODELS   •   INSTALLATION INSTRUCTIONS
TAbLe OF CONTeNTS
Introduction ...................................... page  2
massachusetts and New York
  Requirements .........................page  3
General Information .......................... page  3
Location ............................................ page  4
Appliance Specifications ................... page  5
Clearances ........................................ page  5
Gas Vent Rule ................................... page  5
Fireplace Installation:
  Typical Installation Sequence ......... page  6
  Framing Specifications ................... page  6
  Pre-Installation Notes ..................... page  6
  Installing the Fireplace:
  Step 1.  Construct Appliance
   
      Framing ......................page  6
  Step 2.  Route Gas Line .................page  7
  Step 3.  Position Appliance ............page  7
  Step 4.  Install Vent System and 
   
      Exterior Termination ...page  7
  Step 5.  Field Wiring; Install (Optional)  
   
      Wall Switch ................page  8
  Step 6.  Connect to Gas Line .........page  8
  Step 7.  Install (Optional) Outside  
   
      Air Kit .........................page  9
  Step 8.  Install Logs and 
   
      Glowing Embers .........page  10
Appliance Operation:
  Step 9.  Check Appliance
     
      Operation ....................page  10
     
Manual Limit Switch ........ page  10
     
Millivolt Checkout ............ page  10
     
Electronic Checkout ......... page  10
  Step 10.  Adjust Burner ...................page  11
  Step 11. Attach "Safety-in-
   
Operation" Warnings ..... page  12
Finishing Requirements .................... page  13
Cold Climate Insulation ..................... page  13
Installation Accessories .................... page  13
Gas Conversion Kits ...................page 14
This installation manual will help you obtain a 
safe, efficient, dependable installation for your 
appliance and vent system. 
please read and understand these instruc-
tions before beginning your installation.
INTROdUCTION
The millivolt appliances are designed to operate 
on either natural or propane gas. A millivolt gas 
control valve with piezo ignition system provides 
safe, efficient operation.
The  electronic  appliances  are  designed  to 
operate on either natural or propane gas. An 
electronic  intermittent  pilot  system  provides 
safe,  efficient  operation.  External  electrical 
power is required to operate these units.
These appliances comply with National Safety 
Standards and are tested and listed by Warnock 
Hersey (Report No. 3106807) to ANSI Z21.50, 
latest edition (in Canada, CSA 2.22, latest edi-
tion), and CAN/CGA-2.17-M91 in both USA and 
Canada, as vented gas fireplaces.
Installation  must  conform  to  local  codes.  In 
the absence of local codes, installation must 
comply with the current National Fuel Gas Code, 
ANSI Z223.1 (NFPA 54). (In Canada, the current 
CAN/CGA  B149  installation  code.)  Electrical 
wiring must  comply with local codes.  In the 
absence of local codes, installation must be in 
accordance with the National Electrical Code, 
NFPA 70, latest edition. (In Canada, the current 
CSA C22.1 Canadian Electric Code.)
dO  NOT  ATTempT  TO  ALTeR  OR  mOdIFY  
THe CONSTRUCTION OF THe AppLIANCe OR 
ITS  COmpONeNTS.  ANY  mOdIFICATION  OR 
ALTeRATION  mAY  vOId  THe  WARRANTY,  
CeRTIFICATION ANd LISTINGS OF THIS UNIT.
Children and adults should be alerted to the 
hazards  of  high  surface  temperature  and 
should stay away to avoid burns or clothing 
ignition. 
Les enfants et les adultes devraient être infor-
més des dangers que posent les températures 
de surface élevées et se tenir à distance afin 
d’éviter des brûlures ou que leurs vêtements 
ne s’enflamment.
DO  NOT  ATTEMPT  TO  ALTER  OR  MODIFY 
THE CONSTRUCTION OF THE APPLIANCE OR 
ITS COMPONENTS.  ANY MODIFICATION OR 
ALTERATION  MAY    VOID  THE  WARRANTY, 
CERTIFICATION AND LISTINGS OF THIS UNIT.
       WARNING 
Young children should be care-
fully supervised when they are 
in the same room as the appli-
ance. Toddlers, young children 
and others may be susceptible 
to accidental contact burns.  A 
physical barrier is recommended 
if there are at risk individuals in 
the house.  To restrict access to 
a fireplace or stove, install an 
adjustable  safety  gate  to  keep 
toddlers,  young  children  and 
other at risk individuals out of 
the  room  and  away  from  hot 
surfaces.
       AVERTISSEMENT 
Les jeunes enfants devraient être 
surveillés étroitement lorsqu’ils 
se trouvent dans la même pièce 
que l’appareil. Les tout petits, 
les jeunes enfants ou les adultes 
peuvent subir des brûlures s’ils 
viennent en contact avec la sur-
face chaude.  Il est recommandé 
d’installer une barrière physique 
si des personnes à risques habi-
tent la maison.  Pour empêcher 
l’accès à un foyer ou à un poêle, 
installez une barrière de sécu-
rité; cette mesure empêchera les 
tout petits, les jeunes enfants et 
toute  autre  personne  à  risque 
d’avoir accès à la pièce et aux 
surfaces chaudes.
       
WARNING
B-Vent  appliances  are  not 
designed to operate in negatively 
pressured environments (pres-
sure within the home is less than 
pressures outside). Significant 
negatively  pressured  environ-
ments caused by weather, home 
design,  or  other  devices  may 
impact  the  operation  of  these 
appliances.    Negative  pres-
sures may result in poor flame 
appearance, sooting, damage to 
property and/or severe personal 
injury.  Do  not  operate  these 
appliances  in  negatively  pres-
sured environments.
       WARNING 
Improper  installation,  adjust-
ment,  alteration,  service  or 
maintenance  can  cause  injury 
or  property  damage.    Refer  to 
this manual.  For assistance or 
additional  information  consult 
a  qualified  installer,  service 
agency or the gas supplier.