sentrol zxled12 Manual Do Utilizador

Página de 64
21
Walk Test
To perform a walk test:
1.
Press              .
2.
Enter passcode:                                                         .
3.
Press              .
4.
Open or activate each sensor.  As each sensor is opened, listen for an
audible and visual indication to occur at the Control Station indicating
the sensor is working properly.  When all sensors have been opened,
return to the Control Station.
5.
Press and hold              to see any zones that have not been tested.
If you opened a sensor and the Control Station indicates that it was
not tested, it may be faulty.  Retest the sensor or contact your Security
Company Representative.
6.
Press
           to quit.
Testing Your System
It is recommended that all tests be performed on a weekly basis.  Your
system must be OFF to perform these tests.  There are six (6) options
available.
OPTIONAL FEATURES
TESTING YOUR SYSTEM
1
Walk
Verifies that all system zones are operating properly
2
Battery
Verifies that the system battery is fully charged
3
Bell
Verifies that the system audibles are operating properly
4
Communicator
Verifies that the system communicates with the Central
Station
5
Keypad
Verifies that the Control Station lights operate properly
6
RF Signal Strength Tests the signal strength of wireless sensors 
(ZX400/ZX410 only)
1
8
CLEAR
1