sentrol zxlcd Manual Do Utilizador

Página de 64
29
RF Signal Strength   
(ZX400/ZX410/ZX440F only)
If your system includes wireless sensors, then you can test the strength of
signals from these sensors by performing an RF Signal Strength test.  The
strength of a signal can be affected by a low battery condition on the
sensor or changes in the environment due to furniture or appliances.
To test the signal strength of selected RF Zones:
1.
Press              .  The Control Station will display:
2.
Enter passcode:
       The Control Station will display:
3.
Press              .  The Control Station will display:
4.
Enter a number between 13 and 28 to select a wireless sensor to
test. See Protection Zones for a list of zone numbers and descriptions.
Press               . The Control Station will display one of the following:
5.
Repeat step 4 or press              to exit.
DEVICE 13
NO DEVICE
TESTING YOUR SYSTEM
8
FOR TESTS
ENTER PASSCODE
ENTER 1-6 TO
SELECT A TEST
6
DEVICE 00
SELECT RF DEVICE
DEVICE 13
LOW SIGNAL
DEVICE 13
ACCEPTABLE
DEVICE 13
STRONG SIGNAL
The selected zone is not RF or is missing.
Call your Installation Representative.
CLEAR
ENTER