Puls ML60.241 Power Supply Guia De Especificação

Página de 22
 
 
ML60.241
 
 
MiniLine 
 
24V,
 
2.5A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
1. I
NTENDED 
U
SE
 
This device is designed for installation in an enclosure and is intended for the general use such as in industrial control, 
office, communication, and instrumentation equipment. 
Do not use this power supply in aircraft, trains, nuclear equipment or similar systems where malfunction may cause 
severe personal injury or threaten human life. 
This device is designed for use in non-hazardous, ordinary or unclassified locations. 
 
 
2. I
NSTALLATION 
R
EQUIREMENTS
 
This device may only be installed and put into operation by qualified personnel. 
This device does not contain serviceable parts. The tripping of an internal fuse is caused by an internal defect. 
If damage or malfunction should occur during installation or operation, immediately turn power off and send unit to 
the factory for inspection.  
Mount the unit on a DIN-rail so that the output terminals are located on top and input terminal on the bottom. For 
other mounting orientations see de-rating requirements in this document. 
This device is designed for convection cooling and does not require an external fan. Do not obstruct airflow and do 
not cover ventilation grid (e.g. cable conduits) by more than 30%! 
Keep the following installation clearances:  
40mm on top, 20mm on the bottom 
Left / right: 0mm (or 15mm in case the adjacent device is a heat source; in example another power supply….). 
 
WARNING
  Risk of electrical shock, fire, personal injury or death. 
-  Do not use the power supply without proper grounding (Protective Earth). Use the terminal on the input block for 
earth connection. 
-  Turn power off before working on the device. Protect against inadvertent re-powering. 
-  Make sure that the wiring is correct by following all local and national codes. 
-  Do not modify or repair the unit. 
-  Do not open the unit as high voltages are present inside. 
-  Use caution to prevent any foreign objects from entering into the housing. 
-  Do not use in wet locations or in areas where moisture or condensation can be expected. 
-  Do not touch during power-on, and immediately after power-off. Hot surface may cause burns. 
 
 
Sep. 2010 / Rev. 1.0  DS-ML60.241-EN 
All parameters are specified at 24V, 2.5A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
3/22