Puls QS10.241 Power Supply Guia De Especificação

Página de 27
 
 
QS10.241, QS10.241-A1/ -C1/ -D1
 
 
Q-Series 
24V,
 
10A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
9.  E
FFICIENCY AND 
P
OWER 
L
OSSES
 
 
 
 
AC 100V 
AC 120V 
AC 230V 
 
Efficiency  
typ. 
91.5% 
92.6% 
93.5% 
at 24V, 10A 
Average efficiency *) 
typ. 
91.7% 
92.4% 
92.4% 
25% at 2.5A, 25% at 5A, 25% 
at 7.5A. 25% at 10A 
Power losses 
typ. 
4.4W 
4.9W 
6.1W 
at 24V, 0A 
 
typ. 
22.4W 
19.1W 
16.7W 
at 24V, 10A 
*)   The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25% 
of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100% 
of the nominal load for the rest of the time. 
 
 
 
Fig. 9-1 
Efficiency vs. output current at 24V, 
typ 
 
Fig. 9-2  Losses vs. output current at 24V, typ.  
 
Efficiency
2
3
4
5
6
7
8
9
10A
86
87
88
89
90
91
Output Current
92
93
94%
A...100Vac
B... 120Vac
C... 230Vac
A
B
C
 
Power Losses
0
1
2
3
4
5
6
7
10A
0
3
12
15
18
Output Current
21
24W
8
9
A
B
C
6
9
A...100Vac
B... 120Vac
C... 230Vac
 
 
Fig. 9-3 
Efficiency vs. input voltage at 24V, 
10A, typ. 
 
Fig. 9-4  Losses vs. input voltage at 24V, 10A, 
typ. 
 
Efficiency
10/27
85
120
155
190
225 260Vac
88
89
90
91
Input Voltage
92
93
94%
 
Power Losses
9
12
15
18
21
Input Voltage
24
27W
85
120
155
190
225 260Vac
 
Nov. 2011 / Rev. 2.1 DS-QS10.241-EN 
All parameters are specified at 24V, 10A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany