Molex SST-ESR2-CLX-RLL Backplane Module Guia De Especificação

Página de 2
 
 
1 Ethernet + 2 Serial Channels 
For the Allen-Bradley
®
 ControlLogix
®
 Controller 
 
Overview 
The BradCommunications
 SST
 Ethernet / Serial module connects Rockwell 
Automation
®
 ControlLogix
®
 controllers to Modbus networks. Each module has 1 
Ethernet and 2 Serial communication channels that act as independent Modbus 
TCP Client/Server and Modbus Master or Slave protocols to exchange data with 
other Modbus compatible devices. 
 
The SST module acts as a 1756 input/output module between the Modbus network 
and the ControlLogix backplane. The data transfer from the SST
 module to the 
ControlLogix processor supports 2 modes; a direct mode allowing mapping of 
Modbus data in I/O processor image (496 inputs bytes / 496 output bytes) and a 
messaging mode (based on CIP transaction) allowing access to Modbus data 
images stored in 32K registers of the SST
 module’s memory. 
 
The SST module has a USB port on the front panel which can be used for the 
startup of the module when the user configuration is stored to a USB key.  This can 
also be beneficial if a breakdown occurs, allowing a very quick startup to occur with 
a new SST module. 
  
Configuration and Diagnostics 
Save your time, the SST module doesn’t require any ladder logic programming to 
be used. The configuration is created using a PC-based Windows console software 
connected via RLL (Remote Link Library) functionality allowing a remote access to 
the SST module for the configuration and the diagnostics through Rockwell network 
architectures (Ethernet/ControlNet/DeviceNet
). 
  
The SST console allows the user to define the network parameters, Modbus 
devices and the cyclic data exchanges. The console includes a user configuration 
manager offering services for download, upload, copy, and rename of user 
configurations.  With this, a user can very easily and quickly create a new 
configuration to initialize and start a SST module. 
 
The SST console includes diagnostic tools to help with the commissioning and 
monitoring of the Modbus connection. These tools allow access in read and write 
modes to the Modbus slaves or to monitor and modify the module’s internal data 
shared bound for a Modbus Master. Thus, the user-friendly tools are available for 
controlling the communication in commissioning phase (PROG mode). This same 
information is also available in production (RUN mode) through status words 
making it possible for the user to manage the execution of the control application in 
its ladder logic. 
The BradCommunications
 SST communications module 
connects your Rockwell Automation ControlLogix
®
 
controller with up to 1 Ethernet Modbus TCP and 2 Serial 
Modbus networks. 
Features 
Save money!
  
1 Ethernet and 2 RS232/RS485 
Serial Modbus channels on a 
single slot - 1756 backplane 
compatible 
Save time!
  
No ladder logic to write for 
configuration and data transfer 
between module and 
ControlLogix processor 
Boot user configuration and 
update firmware module through 
integrated USB port  
Data format: Bit, Byte, Word, 
Dword, Float 
RLL feature : configure and 
diagnose Modbus network 
remotely via A-B RSLinx
®
  
Advanced Windows configuration 
and diagnostics tools 
Up to 8 SST™  modules can be 
used in one ControlLogix rack 
Support local and remote 
chassis 
Protocols 
Modbus TCP Client /Server 
Modbus Serial Master or Slave 
(RTU / ASCII) 
Typical Applications 
SCADA / supervisory 
communication 
Integration of legacy Modbus 
devices 
Bridge Rockwell networks to 
Modbus compatible devices 
 
 
03 Apr. 08 
DW2007211