Molex SST-ESR2-CLX-RLL Backplane Module 规格指南
1 Ethernet + 2 Serial Channels
For the Allen-Bradley
®
ControlLogix
®
Controller
Overview
The BradCommunications
™
SST
™
Ethernet / Serial module connects Rockwell
Automation
®
ControlLogix
®
controllers to Modbus networks. Each module has 1
Ethernet and 2 Serial communication channels that act as independent Modbus
TCP Client/Server and Modbus Master or Slave protocols to exchange data with
other Modbus compatible devices.
The SST module acts as a 1756 input/output module between the Modbus network
and the ControlLogix backplane. The data transfer from the SST
TCP Client/Server and Modbus Master or Slave protocols to exchange data with
other Modbus compatible devices.
The SST module acts as a 1756 input/output module between the Modbus network
and the ControlLogix backplane. The data transfer from the SST
™
module to the
ControlLogix processor supports 2 modes; a direct mode allowing mapping of
Modbus data in I/O processor image (496 inputs bytes / 496 output bytes) and a
messaging mode (based on CIP transaction) allowing access to Modbus data
images stored in 32K registers of the SST
Modbus data in I/O processor image (496 inputs bytes / 496 output bytes) and a
messaging mode (based on CIP transaction) allowing access to Modbus data
images stored in 32K registers of the SST
™
module’s memory.
The SST module has a USB port on the front panel which can be used for the
startup of the module when the user configuration is stored to a USB key. This can
also be beneficial if a breakdown occurs, allowing a very quick startup to occur with
a new SST module.
Configuration and Diagnostics
Save your time, the SST module doesn’t require any ladder logic programming to
be used. The configuration is created using a PC-based Windows console software
connected via RLL (Remote Link Library) functionality allowing a remote access to
the SST module for the configuration and the diagnostics through Rockwell network
architectures (Ethernet/ControlNet/DeviceNet
be used. The configuration is created using a PC-based Windows console software
connected via RLL (Remote Link Library) functionality allowing a remote access to
the SST module for the configuration and the diagnostics through Rockwell network
architectures (Ethernet/ControlNet/DeviceNet
™
).
The SST console allows the user to define the network parameters, Modbus
devices and the cyclic data exchanges. The console includes a user configuration
manager offering services for download, upload, copy, and rename of user
configurations. With this, a user can very easily and quickly create a new
configuration to initialize and start a SST module.
The SST console includes diagnostic tools to help with the commissioning and
monitoring of the Modbus connection. These tools allow access in read and write
modes to the Modbus slaves or to monitor and modify the module’s internal data
shared bound for a Modbus Master. Thus, the user-friendly tools are available for
controlling the communication in commissioning phase (PROG mode). This same
information is also available in production (RUN mode) through status words
making it possible for the user to manage the execution of the control application in
its ladder logic.
The BradCommunications
™
SST communications module
connects your Rockwell Automation ControlLogix
®
controller with up to 1 Ethernet Modbus TCP and 2 Serial
Modbus networks.
Modbus networks.
Features
y
Save money!
1 Ethernet and 2 RS232/RS485
Serial Modbus channels on a
single slot - 1756 backplane
compatible
Serial Modbus channels on a
single slot - 1756 backplane
compatible
y
Save time!
No ladder logic to write for
configuration and data transfer
between module and
ControlLogix processor
configuration and data transfer
between module and
ControlLogix processor
y
Boot user configuration and
update firmware module through
integrated USB port
update firmware module through
integrated USB port
y
Data format: Bit, Byte, Word,
Dword, Float
Dword, Float
y
RLL feature : configure and
diagnose Modbus network
remotely via A-B RSLinx
diagnose Modbus network
remotely via A-B RSLinx
®
y
Advanced Windows configuration
and diagnostics tools
and diagnostics tools
y
Up to 8 SST™ modules can be
used in one ControlLogix rack
used in one ControlLogix rack
y
Support local and remote
chassis
chassis
Protocols
y
Modbus TCP Client /Server
y
Modbus Serial Master or Slave
(RTU / ASCII)
(RTU / ASCII)
Typical Applications
y
SCADA / supervisory
communication
communication
y
Integration of legacy Modbus
devices
devices
y
Bridge Rockwell networks to
Modbus compatible devices
Modbus compatible devices
03 Apr. 08
DW2007211