Puls ML15.121 Power Supply Guia De Especificação

Página de 23
 
 
ML15.121
 
 
MiniLine-2 
 
12V,
 
1.3A,
 
S
INGLE 
P
HASE 
I
NPUT
 
 
 
22.11. U
SE IN A 
T
IGHTLY 
S
EALED 
E
NCLOSURE
 
When the power supply is installed in a tightly sealed enclosure, the temperature inside the enclosure will be higher 
than outside. In such situations, the inside temperature defines the ambient temperature for the power supply. 
The following measurement results can be used as a reference to estimate the temperature rise inside the enclosure. 
The power supply is placed in the middle of the box, no other heat producing items are inside the box  
Enclosure: 
 
 
Rittal Type IP66 Box PK 9510 100, plastic, 130x130x75mm 
Input: 
   230Vac 
 
 
Case A: 
Load: 
 
   12V, 
1.3A; 
load 
is placed outside the box 
Temperature inside the box:  
38.9°C  (in the middle of the right side of the power supply with a distance of 1cm) 
Temperature outside the box:  
28.0°C 
Temperature rise: 
 
10.9K 
 
Case B: 
Load:    
 
 
12V, 1.05A; (=80%) load is placed outside the box 
Temperature inside the box:  
33.9°C  (in the middle of the right side of the power supply with a distance of 1cm) 
Temperature outside the box:  
27.4°C 
Temperature rise: 
 
8.5K 
 
 
Mar. 2013 / Rev. 2.1  DS-ML15.121-EN 
All parameters are specified at 12V, 1.3A, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 
www.pulspower.com   Phone +49 89 9278 0    Germany 
22/23