E/M Type II provides a four−wire fully−looped arrangement that provides full isolation between the
trunks and signaling units. The following table displays the sent signal states for active/not active
signaling. The RBS grounds its M−lead to signal a seizure. The other device applies battery to its
M−lead to signal a seizure. Prod-El SRB expect to see active conditions on the E−lead and signal
active to the remote device on M−lead.
E/M Type V Interface Model
E/M Type V interface is a symmetrical two−wire lead arrangement that signals in both directions by
means of open for not active and ground for active signalling. The following table displays the sent
signal states for active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other
device applies battery to its M−lead to signal a seizure. Prod-El SRB expect to see active conditions
on the E−lead and signal active to the remote device on M−lead.
E/M Proprietary Type Interface Model
E/M Proprietary Type provides a four−wire fully−looped arrangement that provides full isolation
between the trunks and signaling units. The following table displays the sent signal states for
active/not active signaling. The RBS grounds its M−lead to signal a seizure. The other device applies
battery to its M−lead to signal a seizure. Prod-El SRB expect to see active conditions on the E−lead
and signal active to the remote device on M−lead.
M+
M-
E+
E-
SRB side
SRB side