Hytronik Electronics Co. Ltd HC418VRF Manual Do Utilizador

Página de 4
120~277VAC 60Hz.
Model NO.:HC418V/RF
Model NO.:HC424RF
RF antenna
Rotary coding switch
Stand-by period
Stand-by dimming level
Detection area
Daylight threshold
Stand-by period
Stand-by dimming level
Hold-time
Rotary coding switch
RF Antenna
LED indication
Daylight sensor
Block A6, Nan’pu Science & Technology Park, Hao’si, 
Shajing Street, Bao’an District, Shenzhen, P.R.C. 518104
T: 86 755 27322200                 F: 86 755 27308687 
E: info@hytronik.com            W: www.hytronik.com 
HYTRONIK  ELECTRONICS CO.,LTD
2.2 Keep the RF antenna at least 3cm away from the driver or ballast.
1.4
2.1 Ensure that the electricity supply is switched off completely before installing or servicing this product.
PROTECTION LEVEL
STANDBY PERIOD
STANDBY DIMMING LEVEL
WORKING TEMPERATURE
HC418V/RF
Up to 30 meters indoor transmission and 100 
meters in open area.
Fixed address coding with 10 channels (max. 10 groups)
Diameter Max. 12m
5s~30min
-20 ~ +60
0s, 10s~1h, +
0s, 10s~1h, +
10~50%
10~50%
-20 ~ +60
Max. 6m
Max. 6m
HC424RF
120~277VAC  60Hz
120~277VAC  60Hz
200W@120VAC; 500W@277VAC(capatitive Load)