Service Buttons
A Smart-Sync Bridge has two service buttons located on the front of the device.
Service buttons specifications
Action
Button
Use
No
Network
mode
(press
and hold
for 3
seconds)
During installation, when a Ethernet or Wi-Fi network is not available, the device must be set to
During this mode, the device does not connect to the facility's network.
Dismiss
LED
Alert
During an Alarm state, pressing the silence button stops the LED from flashing.
Initiate
Manual
Check-
in
Pressing the check-in button during normal operation initiates a check-in to your OneVue
Account and its connection to a NTP Server to obtain UTC time. During a check-in, all data is
transmitted to your OneVue account and any pending updates are downloaded to the device.
When the check-in button is pressed, the LCD display indicates its connection by the showing the
number sequence below.
Number 1 displayed - radio powered on
Numbers 12 displayed - connected to facility's Ethernet or Wi-Fi network
Numbers 123 displayed - connected to NTP Server and obtained UTC Time
Numbers 1234 displayed - connected to OneVue; sends Smart-Sync Clock statuses to OneVue
and downloads update pending settings
During an active check-in connection, additional pressing of the check-in button is ignored.
If a check-in fails, all data is stored in the device's non-volatile memory; up to a maximum of
1400 clocks.