Xplore Technologies Corp. MC7750 Manual Do Utilizador

Página de 100
Power
Rev 4  Sep.11
Proprietary and Confidential - Contents subject to change
47
Module power states
The module has five power states, as described in 
. 
Table 6-4:  Miscellaneous DC power consumption
1
 
Signal
Description
Current
Unit
Notes / configuration
Typ
Max
VCC
Module OFF leakage 
current
490
830
A
Full operating temperature range
USB active current 
18
25
mA
High speed USB connection, C
L
 = 50 pF 
on D+ and D- signals
Inrush current
750
3000
mA
Assumes power supply turn on time 
> 100
µ
s
Dependent on host power supply 
rise time.
GPS signal 
connector
Active bias on GPS port 
3.3 
(100 mA)
V
GPS connector 1 in 
.
1.
All measurements are preliminary values
Table 6-5:  Module power states 
State
Details
Host is powered
Module is powered
USB inter
fa
ce active
RF enabled
Normal
(Default 
state)
Module is active
Default state when VCC is first applied in the absence of W_DISABLE_N control
Module is capable of placing / receiving calls, or establishing data connections on the 
wireless network
Current consumption is affected by several factors, including:
Radio band being used
Transmit power
Receive gain settings
Data rate
Number of active Tx time slots
Low power
(‘Airplane 
mode’)
Module is active
State is controlled by host interface using software commands:
Sleep
Normal state of module between calls or data connections
Module cycles between wake (polling the network) and sleep, at network provider-
determined interval.