10. Durability 
 
10.1. Ambient Light Immunity 
Scanning performance is guaranteed when the barcode surface is illuminated as 
follows. 
 
Incandescent light   : 0 ~ 4,000 lx 
Fluorescent light 
: 0 ~ 4,000 lx (excluding high-frequency 
lighting) Sunlight 
: 0 ~ 80,000 lx 
 
<Conditions> 
Barcode Test Sample 
OPTOELECTRONICS test chart 
PCS = 0.9, Resolution 0.25 mm, 9-digit Code 39, Quiet 
Zone 10 mm, N/W Ratio = 1:2.5 
Distance 
100 mm from the front edge of the 
scanner. Angles 
Pitch: α = 0°, Skew: β = 15°, Tilt: γ = 0° 
Curvature 
R = 
∞ 
Power Voltage 
3.7 V 
 
* Be sure that direct light or specular reflection does not enter the light receiving 
section of the OPN-2006. 
 
 
10.2. Vibration Strength (without packing) 
There shall be no sign of malfunction after the following vibration test. 
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at 
an accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a 
cycle) in the non-operating state. Repeat this in each X, Y and Z direction. 
 
 
10.3. Vibration Strength (in individual packing) 
There shall be no sign of malfunction after the following vibration test. 
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at 
an accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a 
cycle) in the individual packaged state. Repeat this in each X, Y and Z direction.