Opticon Sensors Europe BV OPN2006 Manual Do Utilizador
18
OPN-2005
Specifications Manual
10. Durability
10.1. Ambient Light Immunity
Scanning performance is guaranteed when the barcode surface is illuminated as
follows.
follows.
Incandescent light : 0 ~ 4,000 lx
Fluorescent light
Fluorescent light
: 0 ~ 4,000 lx (excluding high-frequency
lighting) Sunlight
: 0 ~ 80,000 lx
<Conditions>
Barcode Test Sample
OPTOELECTRONICS test chart
PCS = 0.9, Resolution 0.25 mm, 9-digit Code 39, Quiet
Zone 10 mm, N/W Ratio = 1:2.5
PCS = 0.9, Resolution 0.25 mm, 9-digit Code 39, Quiet
Zone 10 mm, N/W Ratio = 1:2.5
Distance
100 mm from the front edge of the
scanner. Angles
Pitch: α = 0°, Skew: β = 15°, Tilt: γ = 0°
Curvature
R =
∞
Power Voltage
3.7 V
* Be sure that direct light or specular reflection does not enter the light receiving
section of the OPN-2006.
section of the OPN-2006.
10.2. Vibration Strength (without packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at
an accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a
cycle) in the non-operating state. Repeat this in each X, Y and Z direction.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at
an accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a
cycle) in the non-operating state. Repeat this in each X, Y and Z direction.
10.3. Vibration Strength (in individual packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at
an accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a
cycle) in the individual packaged state. Repeat this in each X, Y and Z direction.
Vibration test: Increase the frequency of the vibration from 10 Hz to 100 Hz at
an accelerated velocity of 19.6 m/s2 (2.0 G) for 30 minutes (60 minutes for a