Opticon Sensors Europe BV OPN2006 Manual Do Utilizador

Página de 22
19 
 
 
OPN-2005
 
Specifications Manual
 
 
 
 
 
 
10.4. Drop Impact Strength (without packaging) 
There shall be no sign of malfunction after the following drop test. 
Drop test: Drop the scanner 3 times (18 times in total), at each 6 face, from a height of 
150 cm onto a concrete floor as shown below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 13: Drop Test
 
 
10.5. Electrostatic Discharge Immunity 
Air discharge: 
8 kV Max. (No malfunction)  
15 kV Max. (No destruction) 
Contact discharge: 
4 kV Max. (No malfunction) [Discharged from the frame of the 
USB connector.] 
10 kV Max. (No destruction) 
Measurement 
environment: 
Use electrostatic testing device compliant with IEC 61000-4-2 
Discharge 
resistance: 
330 Ω 
Capacitor charging: 
150 pF 
 
 
10.6. MTBF 
MTBF (Mean Time Between Failures)  
30,000 hours (excluding the following parts) 
Laser diode :  
 
 
 
10,000 hours 
Mirror scan unit :  
 
 
 
10,000 hours