Forced Re-initialization:
 
 
                                                      
F
Motor
Unit
Unit
Mode
Open
Close
 
 
 
 
When an error is noted in the operation of the motor unit (indicated by a Flashing 
RED light on the wall plate or status indicator), the unit can be “Reset” by forcing 
a re-initialization via the remote control. 
 
1)  Shut off the power* to the unit for 20 seconds.  Upon reapplication of 
power the unit should automatically close and stop.   
2)  Verify motor operation at this point, since cycling the power may correct 
some problems.  
3)  Using the “Unit” key select the number which you programmed into the 
control unit for the selected window or skylight.  Note: A Reset cannot be 
activated in the “All” Unit setting. 
4)  Using the “Mode” key select the “Motor” function. 
5)  Press both the “Unit” and “Mode” keys down simultaneously and hold 
them until the “Motor” icon on the display blinks twice. Watch to be sure 
the Unit Code does not change during the button press. If it does you will 
have to return to step 3. 
6)  The selected unit should begin to run through a full open and closed cycle 
during which a Red light should be seen at the wall switch plate or status 
indicator.  Watch the unit for obstructions or other problems during this 
procedure.  Take action to correct hardware or window/skylight related 
problems as necessary. 
6)  Repeat this procedure from step 3) until the problem is resolved. 
 
*Power interruption is most easily accomplished by shutting off the specific 
breaker at the homes fuse or power distribution panel.
 
 
 
 
Press Unit & Mode 
buttons together and  