MOUNTING AND SETUP
4.1
The sensor can be mounted on a various selection of surfaces such as walls, buildings,
metal poles, etc. However, regardless of the mounting fixture you choose, the diameter
must be two and one half (2 ½”) inches and must be placed approximately six (6 m)
meters (optimum height) from the ground. The mounting fixture must be extremely rigid
and must be plumb both vertically and horizontally.
metal poles, etc. However, regardless of the mounting fixture you choose, the diameter
must be two and one half (2 ½”) inches and must be placed approximately six (6 m)
meters (optimum height) from the ground. The mounting fixture must be extremely rigid
and must be plumb both vertically and horizontally.
4.2
Position the universal mounting bracket (Figure 4-1, Item 1) above the mounting fixture,
ensuring the stop pin (Figure 4-1, Item 9) is oriented to be at the bottom of the universal
mounting bracket. Slide the clamps down the mount allowing two and one half (2.5 cm)
centimeters of clearance above the top mounting clamp and the top of the mounting
fixture (Figure 4-1, Item 3). Tighten the star nuts on the top and bottom clamps (Figure
4-1, Item 4).
ensuring the stop pin (Figure 4-1, Item 9) is oriented to be at the bottom of the universal
mounting bracket. Slide the clamps down the mount allowing two and one half (2.5 cm)
centimeters of clearance above the top mounting clamp and the top of the mounting
fixture (Figure 4-1, Item 3). Tighten the star nuts on the top and bottom clamps (Figure
4-1, Item 4).
4.3
Loosen the star nuts, one on each side of the universal mounting bracket (Figure 4-1,
Item 5). Rotate the clamp bracket (Figure 4-1, Item 6) until the top of the bracket is
perfectly vertical to the sensor mounting bracket (Figure 4-1, Item 7) as indicated by the
red dotted line. Tighten star nuts (Figure 4-1, Item 5). After the star nuts are tightened,
use a flat blade screwdriver to tighten the universal mounting bracket screws, one on each
side (Figure 4-1, Item 8).
Item 5). Rotate the clamp bracket (Figure 4-1, Item 6) until the top of the bracket is
perfectly vertical to the sensor mounting bracket (Figure 4-1, Item 7) as indicated by the
red dotted line. Tighten star nuts (Figure 4-1, Item 5). After the star nuts are tightened,
use a flat blade screwdriver to tighten the universal mounting bracket screws, one on each
side (Figure 4-1, Item 8).
4.4
Slide the QUPID mounting bracket onto the universal mounting bracket until the QUPID
bracket is resting on the universal mounting bracket stop pin (Figure 4-1, Item 9). Push
in on the spring loaded thumb screws and hand tighten (Figure 4-1, Item 2). After the
screws are hand tight, use a flat blade screwdriver to securely tighten the two screws.
Use compass to bore sight desired angle.
bracket is resting on the universal mounting bracket stop pin (Figure 4-1, Item 9). Push
in on the spring loaded thumb screws and hand tighten (Figure 4-1, Item 2). After the
screws are hand tight, use a flat blade screwdriver to securely tighten the two screws.
Use compass to bore sight desired angle.
Figure 4-1 Sensor Mounting
3
2
1
2.5 cm
4
5
6
7
8
9