- 5 -
RELAY STATES IN A NORMAL (NON-INTRUSION )
MODE
3.5
Route power and alarm cable through the cable clamp located on the bottom of the box
(Figure 3-5, Item 1) and connect wires as shown in Figure 3-6.
(Figure 3-5, Item 1) and connect wires as shown in Figure 3-6.
Figure 3-5 Interface Box Wiring
Figure 3-6 Wiring Schematic
The Form-C relay contacts are brought out to the
Interface connection block as individual, independent
dry contacts.
Absolute maximum rating for these contacts are:
16 Volts and 100 milliamperes maximum
Operation beyond these ratings may cause
permanent damage to the sensor.
The contacts are protected with a self resetting PTC
fuse in the COM line, which may have an initial
resistance of up to 2 ohms (at 22
o
C).
3.6
After wires have been connected, tighten cable clamp (Figure 3-5, Item 1) securely to
hold cable in place
hold cable in place
3.7
Close interface box cover and install screws and screw cover tabs.
1
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 SH
TERMINAL
SIGNAL NAME
1
ALARM N.O.
2
ALARM COM
3
ALARM N.C.
4
FAULT N.O.
5
FAULT COM
6
FAULT N.C.
7
TAMPER N.O.
8
TAMPER COM
9
TAMPER N.C.
10
SELF TEST (1)
11
SELF TEST (2)
12
13
+12V POWER
14
12V RTN
15
CHASSIS GROUND
SH
SENSOR STATE CONTACT STATE DIAGRAM
INTRUSION
(ALARM)
TAMPER
FAULT
Relay contacts close
when in ALARM
state
Relay contacts are
closed when in non-
tamper state
Relay contacts close
When in fault state
when in ALARM
state
Relay contacts are
closed when in non-
tamper state
Relay contacts close
When in fault state
N. C.
COM
N.O
COM
N.O
N. C.
COM
N.O
COM
N.O
N.C
COM
N.O
COM
N.O