ZTE Corporation BS8800C200 Manual Do Utilizador

Página de 167
Chapter 8 Installing Main Antenna Feeder System
Installing Omnidirectional Antenna on
Top-tower
Context
Installation requirements are described as follows:
An installation plane of antenna rack should keep vertical with
the level.
Install a mast of tower arrester singly. The height of mast
meet protective requirements of all antenna arresters. When
an antenna rack extends out of the platform of iron tower, make
sure the antenna within a protective area of 30° downtilt of
arrester top, as shown in
.
F
IGURE
102 A
RRESTER
P
ROTECTIVE
A
REA
1.
Arrester
2.
Antenna
3.
Arrester mast
Make sure an installation direction of antenna rack not affecting
receiving and transmitting performance of directional antenna
as well as direction adjustment.
Make sure the antenna within a protective area of iron arrester.
The distance that the antenna extends out of iron platform is
1 m at least.
Reinforce a rotational mast with an enhanced mast.
The
lengths of a collapsible mast and a rotational mast should be
cut according to on-site condition. Weld a cover board on the
cut section to avoid leakage.
Make sure all welding parts fastened and no faulty or lacking
welding. Suggest adopting galvanized steel for the rack and
covering a layer of antirust sliver-powder paint on the surface
of rack.
Make sure the antenna within a protective area of iron arrester.
The distance from the body of iron tower is 2 m at least.
The axes of antenna should be vertical with the level and the
error should be less than ±1
.
The gain of antenna should be 11dBi and the isolation be 30dB.
Confidential and Proprietary Information of ZTE CORPORATION
111