ZTE Corporation BS8800C200 Manual Do Utilizador

Página de 167
ZXSDR BS8800 C200 Installation Manual
Context
The 120 Ω E1 cable is the transmission cable between ZXSDR
BS8800 C200 and BSC, transmitting the interface message be-
tween ZXSDR BS8800 C200 and BSC.
The appearance of 120 Ω E1 cable is as shown in
. End
A of cable is a DB44 straight plug.
F
IGURE
36 120 Ω E1 C
ABLE
A
PPEARANCE
There are two types of 120 Ω E1: one supports 8 E1 cables and
the other supports 4 E1 cables. The appearances of two cables are
similar, but the number of core wire is different.
Steps
1. Lead the 120Ω E1 cable through a slot on the top into the
cabinet.
2. Lay out the 120 Ω E1 cable along the vertical cable tray at the
right side of cabinet to the B2 connector (E1/T1 cable connec-
tor) of data cable.
Refer to
for the instruction of data cable.
3. Connect the DB44 connector of 120Ω E1 cable to the B2 in-
terface (E1/T1 cable interface) of data cable through the
SA
panel.
E
ND OF STEPS
.
Result
After installation completed, the appearance of 120 Ω E1 cable is
as shown in
.
Installing 100Ω T1 Cable
Prerequisite
Install the
SA
module and data cable.
Context
The 100 Ω T1 cable is the transmission cable between ZXSDR
BS8800 C200 and BSC, transmitting the interface message be-
tween ZXSDR BS8800 C200 and BSC.
The appearance of 100 Ω T1 cable is as shown in
. End
A of cable is a DB44 straight plug.