Hewlett Packard Enterprise Company AP175SDR Manual Do Utilizador

Página de 36
26
Aruba AP-175 Outdoor Access Point
| Installation Guide
Figure 23  Connecting the Ethernet cable
Connecting the Power Cable (AP-175 AC)
The best practice is to connect to AC mains in an outdoor grade weather protected junction box. 
The use of plugs with infrastructure equipment is suitable only for temporary installs where nuisance 
tripping of GFCI plugs is considered tolerable. Should it be required to attach a plug to the cable assemblies, 
the installer is must follow all directions provided with the plug end in a fashion consistent with local 
electrical code.
Use of CKIT-AC-M
CKIT-AC-M is a weatherproof connector kit for an AC power interface. Assembly instructions for this part 
are shipped with the part. All instructions must be followed to ensure proper assembly of the connector 
onto the cable. The required specifications for third party AC power cable used with the CKIT solution are 
as follows:
250V/1A minimum voltage/current rating 
6-12mm diameter 
rated for outdoor use and UV exposure
Figure 24  AC Power Connector PIN OUT on the AP-175AC
!
Installation and service of Aruba products should be performed by Professional Installers in a manner that is 
consistent with the electrical code in force in the jurisdiction of deployment. In many countries this will require a 
licensed electrician to perform this operation. In Japan, this is a Certified Electrician by Ministry of Economy, Trade, 
and Industry.