Identifying Specific Installation Locations
You can mount the 370 Series access point on a wall or pole. Use the AP placement map generated by Aruba’s RF 
Plan software application to determine the proper installation location(s). Each location should be as close as 
possible to the center of the intended coverage area and should be free from obstructions or obvious sources of 
interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have 
been accounted for during the planning phase and adjusted for in RF plan.
Identifying Known RF Absorbers/Reflectors/Interference Sources
Identifying known RF absorbers, reflectors, and interference sources while in the field during the installation 
phase is critical. Make sure that these sources are taken into consideration when you attach an AP to its fixed 
location. Examples of sources that degrade RF performance include:
Cement and brick
Objects that contain water
Metal
Microwave ovens
Wireless phones and headsets
Installing the Access Point
Using Mount Kits
The 370 Series access point can be installed on a wall or attached to a pole by using mount kits:
Service to all Aruba products should be performed by trained service personnel only.
Table 4  
Applicable Mount Kits for 370 Series Access Point
Part Number
Description
JW052A
AP-270-MNT-V1 long mount kit for wall and vertical pole mounting, 300 mm from 
vertical mounting asset.
JW053A
AP-270-MNT-V2 short mount kit for wall and vertical pole mounting, 75 mm from 
vertical mounting asset.
JW054A
AP-270-MNT-H1 mount kit for hanging from inclined or horizontal structure.
JW055A
AP-270-MNT-H2 flush mount kit for wall and ceiling mounting.
The 370 Series access point does not ship with any mount kits. These mount kits are available as accessories 
and must be ordered separately.
For installation instructions on AP-270-MNT-V1, AP-270-MNT-V2, AP-270-MNT-H1 and AP-270-MNT-H2 mount 
kit, please refer to the AP-270-MNT-V1 Installation Guide, AP-270-MNT-V2 Installation Guide, AP-270-MNT-H1 
Installation Guide and AP-270-MNT-H2 Installation Guide 
respectively.
!
CAUTION
This equipment is intended for installation in a RESTRICTED ACCESS LOCATION attached to a pole or installed 
on a wall. Installers should disconnect power before working with or near the AP-377 access point.