Hewlett Packard Enterprise Company APEX037457 Manual Do Utilizador

Página de 19
Aruba 370 Series Outdoor Access Points
| Installation Guide
9
Grounding the Access Point
The grounding must be completed before powering up the access point. The grounding wire should be #8 AWG.
1. Peel the cover of one end of the grounding wire and place the bare grounding wire into the included copper 
lug, and press firmly with the crimping pliers.
2. Fasten the copper lug to the grounding hole on the access point with the included M4 x6 screw. 
Connecting the Ethernet Cable
To connect the Ethernet cable to the access point, perform the following steps using the Ethernet cable glands 
that ships with your access point.
Figure 9  
Installing the Ethernet Cable Gland 
1. Remove the dust cap from the Ethernet port
2. Slide the sealing nut, clip, split grommet and gland body over the cable.
3. Insert the RJ45 connector to the Ethernet port.
4. Screw the gland body onto the Ethernet port.
5. Combine the two split parts of the grommet over the cable, and move it towards the gland body until it 
locates at the recess of the gland body.
6. Move the clip towards the gland body, passing over the grommet, until the wavy end of the clip properly fits 
into the wavy end of the gland body.
7. Screw the sealing nut onto the gland body.
Connecting the Power Cable
WARNING
Failure to use the included Ethernet cable glands can lead to connectivity and POE issues.
The cable is not included and must be purchased separately. Purchase a suitable UV-resistant, outdoor rated, 
CAT 5E or better RJ45 cable for use with the access point.
Sealing Nut
Clip
Gland Body
Split Grommet
Two grommets are provided in the package for use with the Ethernet cables. One is applicable for cables with 
4-6 mm diameter, and another is applicable for cables with 6-10 mm diameter.
!
CAUTION
Installation and service of Aruba products should be performed by Professional Installers in a manner that is 
consistent with the electrical code in force in the jurisdiction of deployment. In many countries this will require 
a licensed electrician to perform this operation. In Japan, this is a Certified Electrician by Ministry of Economy, 
Trade, and Industry.